application of jacketed metal pipeline inspection -尊龙凯时官网入口

2018-01-23 14:55 ytzx

application of jacketed metal pipeline inspection


client unit:daqing oilfield special equipment inspection & testing center

inspection location:no.2 metal plant

testing instrument:weak magnetic detector for oil storage tank

inspection time:november 2017


remark:

according to the on-site inspection conditions, the sensor equipped on this device is a flexible array assembled with 12 high-precision probes. it can be bent and stretched freely to closely attach to the tested workpiece, thus improving inspection accuracy.


nspection site 1:

屏幕快照 2018-01-23 下午3.03.24.png

on-site re-inspection result:

屏幕快照 2018-01-23 下午3.03.40.png

result analysis:

based on the analysis of weak magnetic inspection results, six corrosion pits of varying severity were found in the inspected area. verification carried out by staff entering the tank interior confirmed that the inspection results are fully consistent with the actual situation.


inspection site 2:

屏幕快照 2018-01-23 下午3.04.08.png

result analysis: 

based on the analysis of weak magnetic testing results, a corrosion pit with a corrosion degree of 15% was found at the 680mm position of the tank wall. the same corrosion pit was detected at this position by an ultrasonic thickness gauge. the test results are completely consistent with the ultrasonic inspection data.